The reason for this is the delay in configuring and confirming the work mode.
S: It is recommended to edit the work mode and its settings as quickly as possible, ideally within approximately one minute.
This issue is identified by the “invalid” message appearing for the satellite signal, even though satellite positioning is enabled and the receiver is in an unobstructed area.
S: First, we must configure the base station with coordinates in automatic mode and start it. Once the receiver has determined its geographic position, the base station can then be configured using these known coordinates. In this case, the coordinates should be within +/- 5 meters of the actual location (or, ideally, a precise geodetic point) in either UTM or geographic coordinates (recommended).
This can be fixed by calibrating the compass app on the mobile device before starting the survey.
This offset is caused by the IMU, which is affected by external factors such as magnetic fields and obstacles.
Note: For high-precision surveying, we recommend disabling the IMU and leveling the rod using a spirit level to achieve millimeter-level accuracy.
This issue occurs due to improper shutdown or startup of the device, including rapid reconfiguration of operating modes, which can cause the device to malfunction.
Solution: Reinstall the firmware to restore the device’s functionality.
The FIX solution is displayed only when the RMS values indicate H=0.010 and V=0.010; any deviation from these values is represented by the rover’s position indicator turning yellow, indicating a FLOAT solution.
When naming your project, you should only use 4 to 8 letters and numbers, without any special characters, as the FindX5 application will not recognize it correctly.
This event occurs when the device’s last operating mode was set to RTK Base. When it is powered on again, it will attempt to establish a position. The device will stop beeping once the GNSS receiver has determined a new operating mode.
The fixed solution is achieved under two conditions: first, good LoRa radio communication between the base station and the rover, and second, good positioning accuracy, which depends on the number of satellites, DOP, and environmental conditions.
Note: Ensure that the devices are configured with the same group/channel/frequency to guarantee communication, and consider that there should be no significant obstructions between the base station and the rover for accurate positioning.
The fixed solution is achieved under two conditions: first, reliable communication between the base station and rover, which requires correctly entering the NTRIP CASTER credentials and independent internet access for each receiver; second, good positioning accuracy, which depends on the number of available satellites, the DOP (Dilution of Precision), and environmental conditions.
Note: Ensure that both the base station and rover have the necessary credentials enabled and independent internet access to guarantee communication, and consider the positioning conditions for each device (base station and rover).
If you wish to use a different data collector, our equipment can work with other software programs that support NMEA, such as SurPad, Arcsurv, Survey123, and others.
To access the folder containing CSV and KML files, follow this path: Android > media > com.mettatec.findx > Projects. From there, you can share or delete these files, and they will no longer appear in the “Continue” section of the list.
The credentials to enter in LOCAL NTRIP mode are as follows:
| Field | Value |
|---|---|
| Address | 192.168.4.1 |
| Port | 2101 |
| Username | admin |
| Password | admin |
| Mount point | X5POINT |
The average activation time after purchasing the product is approximately 2 hours; after that, you can use it normally.
Using a free tool called Stakeout Tool, you can import CSV files to perform site layout tasks. You can view the following tutorial for more information:
The mask elevation is 10° and cannot be configured in real time, but it can be edited during post-processing for the PPK method.
Our equipment currently does not support Galileo HAPS or other L-band satellite correction solutions.